SigOFIT Optical-fiber Isolated Probe

Unveil Real Signal You've Never Seen

Based on exclusive SigOFIT™ technology, the SigOFIT optical-fiber

isolated probe has extremely high CMRR and isolation voltage, help

to unveil the whole truth of the signal within bandwidth.

Bandwidth:DC-1GHz

Common Mode Voltage:85kVpk

CMRR:up to 180dB

DC Accuracy:1%

Interface: Universal BNC


SigOFIT Optical-fiber Isolated Probe

Unveil Real Signal You've Never Seen

Based on exclusive SigOFIT™ technology, the SigOFIT optical-fiber

isolated probe has extremely high CMRR and isolation voltage, help

to unveil the whole truth of the signal within bandwidth.

Bandwidth:DC-1GHz

Common Mode Voltage:85kVpk

CMRR:up to 180dB

DC Accuracy:1%

Interface: Universal BNC


Present True Signal

Present True Signal

SigOFIT probe has highest common mode rejection ratio, or CMRR, up to 128dB at 100MHz, over 100dB at 1GHz. It's the ultimate referee of signal fidelity measured by other voltage probes.

Highest Accuracy

Highest Accuracy

As the ultimate referee of signal fidelity, SigOFIT optical-fiber isolated probe delivers highest test accuracy. It has excellent amplitude-frequency characteristics, DC gain accuracy ≤1%, while noise ≤ 0.45mVrms. Zero drift<0.1% (works 5 mins later), gain drift also <1%.

Third-Gen Semiconductor

Best Probe for Third-Gen Semiconductor

SiC & GaN device can switch high voltages in a few nanoseconds, the signal may have high-energy high-frequency harmonics.


Even at the highest bandwidth, the SigOFIT probe still have nearly 100dB CMRR, perfectly suppressed the oscillation caused by high-frequency common-mode noise, no redundant components. It's the best choice for 3rd-gen semiconductor test & measurement.

Safe to Test GaN

Safe to Test GaN

The test leads of SigOFIT probe are short and with coaxial cable transmission, the input capacitance is as low as 1pF minimum, very safe to test GaN.

Optical-fiber Isolated Probe OP

Wide Measurement Range

Unlike traditional differential probes can only test high-voltage signals, SigOFIT probe can be used with different attenuator tips to test differential mode signals from ±0.01V to ±6250V, achieve full-range output and very high signal-to-noise ratio.

SigOFIT Optical-fiber Isolated Probe MOIP10P

Efficient & Affordable

Fastest response, can be tested immediately after power-on; AutoZero completed in less than 1 second, ensures accurate signal output in real time.

Design of GaN, SiC, IGBT Half/Full bridge devices

Applications

* Design of motor drive, power converter, electronic ballast

* Design of GaN, SiC, IGBT Half/Full bridge devices

* Design of inverter, UPS and switching power supply

* Safety test for high voltage, high bandwidth applications

* Power device evaluation

* Current shunt measurements

* EMI & ESD troubleshooting

* Floating measurements

Present True Signal


Present True Signal

SigOFIT probe has highest common mode rejection ratio, or CMRR, up to 128dB at 100MHz, over 100dB at 1GHz. It's the ultimate referee of signal fidelity measured by other voltage probes.

Highest Accuracy


Highest Accuracy

As the ultimate referee of signal fidelity, SigOFIT optical-fiber isolated probe delivers highest test accuracy. It has excellent amplitude-frequency characteristics, DC gain accuracy ≤1%, while noise ≤ 0.45mVrms. Zero drift<0.1% (works 5 mins later), gain drift also <1%.


Third-Gen Semiconductor

Best Probe for Third-Gen Semiconductor

SiC & GaN device can switch high voltages in a few nanoseconds, the signal may have high-energy high-frequency harmonics.


Even at the highest bandwidth, the SigOFIT probe still have nearly 100dB CMRR, perfectly suppressed the oscillation caused by high-frequency common-mode noise, no redundant components. It's the best choice for 3rd-gen semiconductor test & measurement.


Safe to Test GaN


Safe to Test GaN

The test leads of SigOFIT probe are short and with coaxial cable transmission, the input capacitance is as low as 1pF minimum, very safe to test GaN.


Optical-fiber Isolated Probe OP

Wide Measurement Range

Unlike traditional differential probes can only test high-voltage signals, SigOFIT probe can be used with different attenuator tips to test differential mode signals from ±0.01V to ±6250V, achieve full-range output and very high signal-to-noise ratio.


SigOFIT Optical-fiber Isolated Probe MOIP10P

Efficient & Affordable

Fastest response, can be tested immediately after power-on; AutoZero completed in less than 1 second, ensures accurate signal output in real time.


Design of GaN, SiC, IGBT Half/Full bridge devices

Applications

* Design of motor drive, power converter, electronic ballast

* Design of GaN, SiC, IGBT Half/Full bridge devices

* Design of inverter, UPS and switching power supply

* Safety test for high voltage, high bandwidth applications

* Power device evaluation

* Current shunt measurements

* EMI & ESD troubleshooting

* Floating measurements

Key Specifications

Model*

MOIP100P

MOIP200P

MOIP350P

MOIP500P

MOIP800P

MOIP1000P

Bandwidth100MHz200MHz350MHz500MHz800MHz1GHz
Rise Time≤3.5ns≤1.75ns≤1ns≤700ps≤438ps≤350ps
CMRRDC: 180dB
100MHz: 128dB
DC: 180dB
200MHz: 122dB
DC: 180dB
350MHz: 118dB
DC: 180dB
500MHz: 114dB
DC: 180dB
800MHz: 110dB
DC: 180dB
1GHz: 108dB
Differential Voltage Range±6250V

±5000V

Noise<0.45mVrms<0.45mVrms
DC Gain Accuracy1%
Common Mode Voltage Range85kVpk
InterfaceUniversal BNC

* Note: Current model names updated on March 20, 2024, previous model names referred as MOIP01P, and OIP100 (e.g. 100MHz bandwidth).

Key Specifications

Model*

MOIP100P

MOIP200P

MOIP350P

MOIP500P

MOIP800P

MOIP1000P

Bandwidth100MHz200MHz350MHz500MHz800MHz1GHz
Rise Time≤3.5ns≤1.75ns≤1ns≤700ps≤438ps≤350ps
CMRRDC: 180dB
100MHz: 128dB
DC: 180dB
200MHz: 122dB
DC: 180dB
350MHz: 118dB
DC: 180dB
500MHz: 114dB
DC: 180dB
800MHz: 110dB
DC: 180dB
1GHz: 108dB
Differential Voltage Range±6250V

±5000V

Noise<0.45mVrms<0.45mVrms
DC Gain Accuracy1%
Common Mode Voltage Range85kVpk
InterfaceUniversal BNC

* Note: Current model names updated on March 20, 2024, previous model names referred as MOIP01P, and OIP100 (e.g. 100MHz bandwidth).