麦科信
News News

News

A Successful Wrap-Up | Micsig at CPEEC & CPSSC 2026

A Successful Wrap-Up | Micsig at CPEEC & CPSSC 2026

Micsig wrapped up a successful appearance at CPEEC & CPSSC 2026 in Suzhou, showcasing MHO6/MHO3 high-resolution oscilloscopes, MOIP optical isolation probes, DP high-voltage differential probes and CP current probes at Booth E13, Hall B1, and delivering a well-received forum talk on measurement challenges in SiC MOSFET double-pulse testing.

2026-11-10

View More

Micsig Backs the Infineon Cup and Sungrow Cup as the 12th University Power Electronics Application Design Contest Concludes in Suzhou

Micsig Backs the Infineon Cup and Sungrow Cup as the 12th University Power Electronics Application Design Contest Concludes in Suzhou

Micsig served as Platinum Partner and test-equipment sponsor of the Infineon Cup and Sungrow Cup tracks at the 12th University Power Electronics Application Design Contest in Suzhou, supporting 91 finalist teams from 121 universities with MHO3 high-resolution oscilloscopes and MOIP optical-fiber isolated probes through high-dv/dt prototype debugging and verification.

2026-11-09

View More

From 8 Bits to 12: How Vertical Resolution Determines Measurement Accuracy

From 8 Bits to 12: How Vertical Resolution Determines Measurement Accuracy

Small signals riding on large ones get starved of quantization levels on 8-bit scopes. This article shows how 12-bit vertical resolution (4,096 levels, ~24 dB lower quantization noise) works with the Micsig SigOFIT™ MOIP optical-fiber isolated probe (180 dB CMRR, <0.3 mVrms noise floor) to keep small signals readable at 80:1 dynamic range — with no trade-off in bandwidth or capture rate.

2026-11-09

View More

The Value of Optical-Fiber Isolated Probes in EV Traction Drives: The Price of a Bad Measurement Can Be an Inverter Leg

The Value of Optical-Fiber Isolated Probes in EV Traction Drives: The Price of a Bad Measurement Can Be an Inverter Leg

800 V SiC traction inverters leave no margin for distorted measurements — a bad waveform can cost you an inverter leg. This article compares Micsig SigOFIT™ optical-fiber isolated probes (128 dB CMRR at 100 MHz, 1 pF input capacitance) with high-voltage differential probes across turn-off overshoot, bridge-leg crosstalk, and common-mode dv/dt bench tests, with a payback model showing the added investment recovered in under three months.

2026-11-09

View More

The Value of Optical-Fiber Isolated Probes in Switch-Mode Power Supply Design: Don't Let a Distorted Waveform Make the Call

The Value of Optical-Fiber Isolated Probes in Switch-Mode Power Supply Design: Don't Let a Distorted Waveform Make the Call

Distorted waveforms lead to wrong design calls in switch-mode power supply development. This article compares Micsig SigOFIT™ optical-fiber isolated probes (180 dB CMRR, 1.2 GHz, 1 pF input capacitance) with high-voltage differential probes across loop, ringing, and EMI tests — and shows how the added investment pays back in under three months.

2026-11-09

View More

The Value of Optically Isolated Probes in GaN/SiC Device Design: Pay for the Architecture, Save on Misjudgment

The Value of Optically Isolated Probes in GaN/SiC Device Design: Pay for the Architecture, Save on Misjudgment

Why pay more for an optically isolated probe in GaN/SiC designs? See how 1 pF input capacitance, 180 dB CMRR and 85 kVpk common-mode voltage turn measurement accuracy into design payback—across double-pulse testing, dynamic RDS(on) and failure analysis.

2026-11-09

View More

How to Choose the Right Oscilloscope Bandwidth

How to Choose the Right Oscilloscope Bandwidth

Bigger isn't always better. This guide covers the -3 dB definition, the tr ≈ 0.35/BW rise-time rule, the 5th-harmonic requirement for square waves, bandwidth–sample-rate matching, and the bandwidth-vs-noise-floor trade-off — a practical selection method, illustrated with the Micsig MHO high-resolution oscilloscope series.

2026-09-30

View More

Common Pitfalls to Avoid Five Vgs Measurement Mistakes

Common Pitfalls to Avoid Five Vgs Measurement Mistakes

As SiC/GaN devices switch in nanoseconds, inaccurate Vgs makes optimization impossible. This guide breaks down five common pitfalls — single-ended probing of floating gates, trusting only DC CMRR, ignoring probe input capacitance, careless attenuator selection, and confusing pin-side vs. die-internal gate voltage — with practical solutions using the Micsig 3rd-generation SigOFIT optical isolated probe MOIP series.

2026-09-30

View More

Product Launch | Micsig Current Probes CP5005 & CP1503B: The High-Current and High-Bandwidth Duo

Product Launch | Micsig Current Probes CP5005 & CP1503B: The High-Current and High-Bandwidth Duo

Micsig launches two CP-series current probes — the CP5005 and CP1503B — covering both high-current and high-bandwidth measurement needs. The CP5005 offers a maximum input of 500 Arms / 750 Apk with a 20 mm jaw for clamp-on measurement without breaking the circuit, at 5 MHz bandwidth. The CP1503B pushes bandwidth to DC–150 MHz with ≤2.67 ns rise time and 1 mA resolution for GaN/SiC gate-drive currents.

2026-09-29

View More

license