麦科信

Rogowski AC Current Probe (High-Frequency, Flexible)
HRCP Series

Bandwidth: 3 Hz–100 MHz
Coil Cross-section Diameter: 1.6 mm
Typical Accuracy: 2%
Peak Current: 12000 Apk
Interface: Standard BNC

  • Overview

  • Document

  • Download

  • Features

  • Specifications

  • Documents

productdetail

The Micsig HRCP series flexible Rogowski current probe offers bandwidth up to 100 MHz and a maximum measurable current of 12,000 Apk. With nearly zero insertion impedance, the probe minimizes interference with the circuit under test. The coil exhibits high voltage resistance and supports customization of coil cross-sectional diameter, circumference, and lead length to accommodate complex application scenarios.

With typical accuracy up to 2%, the HRCP precisely captures high-frequency, high-current signals, making it well suited for double-pulse dynamic testing of third-generation semiconductors (such as SiC and GaN), as well as real-time monitoring and analysis of power semiconductor switching transient current waveforms.

Accurate High-Frequency Harmonic Capture

Accurate High-Frequency Harmonic Capture


The HRCP series delivers excellent high-frequency performance, easily handling high-speed signals and rapidly changing current waveforms. This helps you observe high-frequency harmonic components when measuring MOSFET Id current.

Standard BNC Interface, Compatible with Any Oscilloscope

Standard BNC Interface, Compatible with Any Oscilloscope


Standard BNC interface, compatible with oscilloscopes of all brands.

Applications

Applications


●Measuring current in motor drives and in particular power quality measurements in VSD, UPS or SMPS circuits
●Double-pulse testing to measure the pin currents of MOSFET and IGBT chips made of materials such as SiC and GaN
●Monitoring currents in small inductors, capacitors, snubber circuits, etc
●Measurement of load current and high-order harmonic current in power electronics
●Measuring small AC currents in the presence of large DC currents
●Measuring high frequency sinusoidal, pulsed or transient currents
●Measuring AC currents in 3-phase supply system
●Measuring the power consumption in semiconductors
●Measurement of 50/60Hz power frequency current
●Power converter development and diagnostics

Model

HRCP-XS Series

Coil Cross-section Diameter

1.6mm

Rogowski Coil Circumference

HRCP***XS-80 :80 mm

Accuracy

2%

Power Supply

DC 12V 

Cable Length

1.5 m (from integrator to Rogowski coil), customizable

Output Impedance

1MΩ

Oscilloscope Interface

Universal standard BNC interface, compatible with oscilloscopes of all brands



HRCP-XS Series

Peak Current

Bandwidth

Output Sensitivity

Peak di/dt

Peak Coil Isolation Voltage

HRCP60XS-80

60Apk

150Hz -100MHz

50mV/A(20X)

8kA/μs

3kVpk 

(Rogowski coil part only)

HRCP120XS-80

120Apk

80Hz-100MHz 

20mV/A(50x) 

20kA/μs

HRCP300XS-80

300Apk

40Hz-100MHz

10mV/A (100X)

40kA/μs

HRCP600XS-80

600Apk

20Hz-100MHz

5mV/A(200X)

80kA/μs

HRCP1200XS-80

1200Apk

10Hz-100MHz

2mV/A (500X)

100kA/μs

HRCP3000XS-80

3000Apk

5Hz-100MHz

1mV/A(1000X)

100kA/μs

HRCP6000XS-80

6000Apk

3Hz-100MHz

0.5mV/A(2000X)

100kA/μs

HRCP12000XS-80

12000Apk

3Hz-100MHz

0.2mV/A(5000X)

100kA/μs





User Manual - High‑Frequency RogowskiAC Current Probe HRCP Series

User Manual - High‑Frequency RogowskiAC Current Probe HRCP Series

File size: 1.06 MB

Update time: 2026-11-16

Brochure - High‑Frequency Rogowski AC Current Probe HRCP Series

Brochure - High‑Frequency Rogowski AC Current Probe HRCP Series

File size: 1.82 MB

Update time: 2026-11-16

license