Rogowski AC Current Probe (High-Frequency, Flexible)
HRCP Series
Bandwidth: 3 Hz–100 MHz
Coil Cross-section Diameter: 1.6 mm
Typical Accuracy: 2%
Peak Current: 12000 Apk
Interface: Standard BNC
-
Features
-
Specifications
-
Documents
The Micsig HRCP series flexible Rogowski current probe offers bandwidth up to 100 MHz and a maximum measurable current of 12,000 Apk. With nearly zero insertion impedance, the probe minimizes interference with the circuit under test. The coil exhibits high voltage resistance and supports customization of coil cross-sectional diameter, circumference, and lead length to accommodate complex application scenarios.
With typical accuracy up to 2%, the HRCP precisely captures high-frequency, high-current signals, making it well suited for double-pulse dynamic testing of third-generation semiconductors (such as SiC and GaN), as well as real-time monitoring and analysis of power semiconductor switching transient current waveforms.
Accurate High-Frequency Harmonic Capture
The HRCP series delivers excellent high-frequency performance, easily handling high-speed signals and rapidly changing current waveforms. This helps you observe high-frequency harmonic components when measuring MOSFET Id current.
Standard BNC Interface, Compatible with Any Oscilloscope
Standard BNC interface, compatible with oscilloscopes of all brands.
Applications
●Measuring current in motor drives and in particular power quality measurements in VSD, UPS or SMPS circuits
●Double-pulse testing to measure the pin currents of MOSFET and IGBT chips made of materials such as SiC and GaN
●Monitoring currents in small inductors, capacitors, snubber circuits, etc
●Measurement of load current and high-order harmonic current in power electronics
●Measuring small AC currents in the presence of large DC currents
●Measuring high frequency sinusoidal, pulsed or transient currents
●Measuring AC currents in 3-phase supply system
●Measuring the power consumption in semiconductors
●Measurement of 50/60Hz power frequency current
●Power converter development and diagnostics
Model | HRCP-XS Series |
Coil Cross-section Diameter | 1.6mm |
Rogowski Coil Circumference | HRCP***XS-80 :80 mm |
Accuracy | 2% |
Power Supply | DC 12V |
Cable Length | 1.5 m (from integrator to Rogowski coil), customizable |
Output Impedance | 1MΩ |
Oscilloscope Interface | Universal standard BNC interface, compatible with oscilloscopes of all brands |
HRCP-XS Series | Peak Current | Bandwidth | Output Sensitivity | Peak di/dt | Peak Coil Isolation Voltage |
|---|---|---|---|---|---|
HRCP60XS-80 | 60Apk | 150Hz -100MHz | 50mV/A(20X) | 8kA/μs | 3kVpk (Rogowski coil part only) |
HRCP120XS-80 | 120Apk | 80Hz-100MHz | 20mV/A(50x) | 20kA/μs | |
HRCP300XS-80 | 300Apk | 40Hz-100MHz | 10mV/A (100X) | 40kA/μs | |
HRCP600XS-80 | 600Apk | 20Hz-100MHz | 5mV/A(200X) | 80kA/μs | |
HRCP1200XS-80 | 1200Apk | 10Hz-100MHz | 2mV/A (500X) | 100kA/μs | |
HRCP3000XS-80 | 3000Apk | 5Hz-100MHz | 1mV/A(1000X) | 100kA/μs | |
HRCP6000XS-80 | 6000Apk | 3Hz-100MHz | 0.5mV/A(2000X) | 100kA/μs | |
HRCP12000XS-80 | 12000Apk | 3Hz-100MHz | 0.2mV/A(5000X) | 100kA/μs |
User Manual - High‑Frequency RogowskiAC Current Probe HRCP Series
File size: 1.06 MB
Update time: 2026-11-16
Brochure - High‑Frequency Rogowski AC Current Probe HRCP Series
File size: 1.82 MB
Update time: 2026-11-16